Practical guides
The ADXL335 provides three analogue axes. A slow controlled orientation change lets you check two outputs together before assuming that an incorrect displayed angle means a fail...
Read the guide →Practical guides
A UART TX waveform does not prove that a half-duplex RS-485 driver was enabled during the message. Compare the driver-enable signal with its data input on the safe logic side.
Read the guide →Practical guides
An unstable buffer can make a steady input look noisy at the output. Compare both nodes and the load condition before blaming the sensor or changing compensation.
Read the guide →Practical guides
A correctly configured D flip-flop can divide a repeating clock by two. Check its data feedback and asynchronous controls before concluding that a flat Q output means a failed c...
Read the guide →Practical guides
A retriggerable one-shot can extend its output when another valid trigger arrives. Compare trigger and output before changing the timing resistor or capacitor.
Read the guide →Practical guides
A Schmitt-trigger input changes state at different rising and falling thresholds. Compare the actual input and output to see whether a slow signal crosses those thresholds as ex...
Read the guide →Practical guides
Before replacing a 555 timer, check its supply, reset state and timing node. A two-trace record can separate a capacitor that never cycles from an output that does not respond.
Read the guide →Practical guides
A PWM-to-DC output depends on both the input pulse pattern and the filter. Two channels help show which side changed, while a steady average alone can hide ripple or clipping.
Read the guide →Practical guides
For a known low-voltage I²S setup, two scope inputs can show whether bit clock and word select are present together. Valid-looking clocks still do not prove that the audio data ...
Read the guide →Practical guides
FNIRSI lists XY display mode for the 2C53P. It plots one input against the other, so a familiar waveform can become a line or ellipse instead of a trace against time.
Read the guide →Practical guides
BSIDE lists AC and DC input coupling for the OT3. Start in DC to understand the signal’s offset, then use AC only for the question that requires it.
Read the guide →Practical guides
Before treating different voltage readings as a fault, compare the same quantity, coupling and operating condition. DC average, RMS, peak and peak-to-peak are different measurem...