DigitalOsc guides
ADXL335 Tilt Readings Look Wrong: Compare Two Analogue Outputs
DigitalOsc editorial team · Updated 20 November 2026
The ADXL335 provides three analogue axes. A slow controlled orientation change lets you check two outputs together before assuming that an incorrect displayed angle means a failed sensor.
Confirm the sensor and breakout wiring
Analog Devices describes the ADXL335 as a three-axis analogue accelerometer with a 1.8-to-3.6 V supply range. Confirm the actual device and breakout schematic; a breakout regulator or added components can change how its external power pin is used. Do not apply a voltage merely because a different sensor module accepts it. Identify the output axes and a compatible reference before connecting the scope.
Use a static test that does not require vibration
Keep the powered board supported and move it slowly between known orientations without stressing leads or shorting exposed pads. This is a qualitative gravitational-response check, not a calibrated acceleration test. Avoid shaking the board as the first experiment: movement, cable forces and a changing reference make it harder to separate a wiring error from the signal you intended to observe.
Compare two output nodes in DC coupling
With suitable high-impedance inputs and a common circuit reference, connect to two documented axis outputs. Start in DC coupling so their offsets remain visible, select a range accommodating the full output and record several seconds of a slow orientation change. The scope’s two channels do not measure all three axes at once. Name the two physical pins in your record rather than labelling them solely from a software variable.
Use the result to separate analogue and software questions
If the physical output changes smoothly while a displayed angle jumps or moves on the wrong axis, inspect pin mapping, ADC scaling and the software calculation. If a node is stationary, check supply, wiring, configured filtering and the relevant axis before declaring a failed sensor. The product documentation explains bandwidth-setting capacitors; their actual values affect how quickly a change appears. Do not copy an arbitrary filter value from an unrelated breakout.
State the limit of the observation
A plausible two-axis response does not calibrate offset, sensitivity, cross-axis error or the final orientation algorithm. A single-channel OT3 can observe one slowly changing axis, while a dual-channel instrument preserves two-axis behaviour in one record. Neither is a replacement for a calibrated motion reference. If the engineering requirement concerns three simultaneous axes or dynamic vibration, specify those acquisition and reference requirements before buying.
Instrument and next step
This is a proposed low-voltage workflow, not a hardware test or a measured fault report. Check the exact instrument, probe and circuit documentation before connecting. If your current equipment already resolves the question, keep using it.
- Check the FNIRSI 2C53P two-channel listing
- Check the BSIDE OT3 single-channel listing
- Compare the current handheld range
DigitalOsc links to Payverza as the retailer. Current price, availability and delivery are shown there; a product link does not certify accessories, isolation or the suitability of a particular circuit.
Sources and scope
- SENSOR official product or application documentation
- Pico Technology: choosing and using an oscilloscope
Sources checked 20 November 2026. Worked numbers are illustrative; they are not measurements of either retail instrument.