ADXL335 Tilt Readings Look Wrong: Compare Two Analogue Outputs

DigitalOsc editorial team · Updated 20 November 2026

The ADXL335 provides three analogue axes. A slow controlled orientation change lets you check two outputs together before assuming that an incorrect displayed angle means a failed sensor.

Confirm the sensor and breakout wiring

Analog Devices describes the ADXL335 as a three-axis analogue accelerometer with a 1.8-to-3.6 V supply range. Confirm the actual device and breakout schematic; a breakout regulator or added components can change how its external power pin is used. Do not apply a voltage merely because a different sensor module accepts it. Identify the output axes and a compatible reference before connecting the scope.

Use a static test that does not require vibration

Keep the powered board supported and move it slowly between known orientations without stressing leads or shorting exposed pads. This is a qualitative gravitational-response check, not a calibrated acceleration test. Avoid shaking the board as the first experiment: movement, cable forces and a changing reference make it harder to separate a wiring error from the signal you intended to observe.

Compare two output nodes in DC coupling

With suitable high-impedance inputs and a common circuit reference, connect to two documented axis outputs. Start in DC coupling so their offsets remain visible, select a range accommodating the full output and record several seconds of a slow orientation change. The scope’s two channels do not measure all three axes at once. Name the two physical pins in your record rather than labelling them solely from a software variable.

Use the result to separate analogue and software questions

If the physical output changes smoothly while a displayed angle jumps or moves on the wrong axis, inspect pin mapping, ADC scaling and the software calculation. If a node is stationary, check supply, wiring, configured filtering and the relevant axis before declaring a failed sensor. The product documentation explains bandwidth-setting capacitors; their actual values affect how quickly a change appears. Do not copy an arbitrary filter value from an unrelated breakout.

State the limit of the observation

A plausible two-axis response does not calibrate offset, sensitivity, cross-axis error or the final orientation algorithm. A single-channel OT3 can observe one slowly changing axis, while a dual-channel instrument preserves two-axis behaviour in one record. Neither is a replacement for a calibrated motion reference. If the engineering requirement concerns three simultaneous axes or dynamic vibration, specify those acquisition and reference requirements before buying.

Instrument and next step

This is a proposed low-voltage workflow, not a hardware test or a measured fault report. Check the exact instrument, probe and circuit documentation before connecting. If your current equipment already resolves the question, keep using it.

DigitalOsc links to Payverza as the retailer. Current price, availability and delivery are shown there; a product link does not certify accessories, isolation or the suitability of a particular circuit.

Sources and scope

Sources checked 20 November 2026. Worked numbers are illustrative; they are not measurements of either retail instrument.