74HC393 Counter Bits Change at Different Times: Fault or Ripple Behaviour?

DigitalOsc editorial team · Updated 21 November 2026

A ripple counter does not promise that every output bit switches at the same instant. Decide whether your circuit needs a stable count or a glitch-free decoded transition before interpreting the trace.

Identify the architecture and selected outputs

TI documents the SN74HC393 as a dual binary ripple counter. Check the exact clock edge, reset behaviour and output order for your package. It is different from a synchronous counter whose output timing has another specification. A visible count sequence can be correct while a combinational circuit observing several bits sees short intermediate states during a transition.

Start with a slow known count

Use compatible safe logic levels, a known reference and a repeatable clock source. Record reset and the selected counter section. Compare the settled output states over several input events before zooming into edges. A wrong output mapping or a held reset should be resolved before deciding that a propagation effect explains everything. Do not connect another source to a clock that is already driven.

Capture one pair at a time with limits

Two inputs can compare clock with one output or compare two outputs. State which pair you actually observed; that record does not simultaneously prove every bit. Use the exact data sheet to interpret edge relationships and required timing. The absence of a visible narrow transition on a basic handheld is not proof of zero skew, and a measured screen offset is not automatically an accurate nanosecond delay.

Choose hardware for the real downstream need

If the application only reads a settled count at a valid time, a brief intermediate state may not matter. If a decoded pulse must be glitch-free, analyse the complete timing and architecture rather than adding arbitrary capacitors to hide the display. The 2C53P supplies two analogue inputs, while the OT3 supplies one; neither turns a ripple counter into a synchronous one. Retain clock, reset, load and capture settings with the evidence.

Choose a handheld for this question

Two simultaneous inputs help with the relationship described here; the FNIRSI 2C53P advertises two channels, 50 MHz and up to 250 MSa/s. Check the actual acquisition mode, capture length and probes. A single-channel OT3 cannot capture two nodes in one event.

DigitalOsc links to Payverza as the retailer. Confirm the exact probes, accessories, current price and delivery before purchase. This is a proposed low-voltage workflow, not an independent hardware test; a battery-powered case does not establish isolated inputs.

Sources and scope

Examples are illustrative, not measured results. Follow the exact device and probe documentation for pinout, voltage, reference and timing limits. Recheck specifications for the version you actually own.