Practical guides
FNIRSI LC1020E: Pick the Right Frequency for an ESR Comparison
Use the capacitor maker’s ESR test frequency and the matching measurement mode. Check the fixture and component conditions before comparing values.
Read the guide →Low-voltage electronics · Clear signals
Make sense of bandwidth, sampling and two-channel measurements before choosing a handheld oscilloscope. Explore the FNIRSI 2C53P and practical low-voltage measurement guides.
Practical guides
Use the capacitor maker’s ESR test frequency and the matching measurement mode. Check the fixture and component conditions before comparing values.
Read the guide →Practical guides
Set the timebase and trigger on an isolated low-voltage test board, then read a 1 kHz square wave from rising edge to rising edge.
Read the guide →Practical guides
Correct stored data does not guarantee a steady display if output enable is modulated. Examine the blanking or dimming signal separately from the shift and latch sequence.
Read the guide →Practical guides
A phototransistor optocoupler output depends on its drive, receiving circuit and load. Do not bridge the two sides with common scope grounds to obtain an attractive two-trace co...
Read the guide →Practical guides
A ripple counter does not promise that every output bit switches at the same instant. Decide whether your circuit needs a stable count or a glitch-free decoded transition before...
Read the guide →Practical guides
A high divider stage can take a long time to change. Before concluding that a CD4060 oscillator stopped, check reset and choose an output whose expected period fits your observa...
Read the guide →Practical guides
A hum at the speaker can originate before the amplifier or inside its supply and wiring arrangement. Compare the documented input and output under controlled conditions before a...
Read the guide →Practical guides
A motor driver can ignore a valid-looking input while asleep or in protection. Inspect its documented logic-side conditions before changing the motor command or probing a switch...
Read the guide →Practical guides
An SPI clock burst can exist without a valid DAC update. Check the exact MCP4921 transfer and update conditions, then relate the analogue result to that event.
Read the guide →Practical guides
If a multiplexer selects the wrong input, the ADC may correctly digitise the wrong sensor. Confirm the address and analogue path before adjusting software scaling.
Read the guide →Practical guides
A visible clock is not enough for a CD4017 sequence. Reset and clock-inhibit conditions can prevent counting, while extra edges can make the display appear to skip.
Read the guide →Practical guides
A serial bit stream can faithfully shift the wrong snapshot. Check when the 74HC165 loads its parallel inputs before changing bit order in software.